03The technical decisions behind it
Heater class
A floor-standing stone heater rather than a wall unit, filled deep with stones. The charge depth is the decision that shapes how the cabin actually feels: a deep charge releases slowly and rounds off the steam when water is thrown, and it recovers temperature faster between throws than a shallow wall unit of the same rating. The trade is footprint — a floor-standing body needs a guard and a defined clearance zone, and that zone has to be drawn into the bench layout, not negotiated on site.
Heat load
We size at roughly 1 kW of heater output per cubic metre of insulated cabin volume, then add about 1 kW per square metre of glazing, because glass gives its heat straight back to the space outside instead of storing it. In a cabin like this the glass door and any glazed panel are the whole of that addition; the rest of the envelope is lined timber over insulation.